Table 2. Stacking sequence of front spar

BL Base Lay-Up Ply Cap Lay-Up Ply
0~830 [45/-45/90/45/-45/90/45/45/90/-45/45/90/-45/04/45] 18 [04/90/05] 10
~1,330 [45/-45/90/45/-45/90/45/45/90/-45/45/90/-45/03/45] 17 [04/90/05] 10
~1,830 [45/-45/90/45/-45/90/45/45/90/-45/45/90/-45/03/45] 17 [04/90/05] 10
~2,330 [45/-45/90/45/-45/90/45/45/90/-45/45/90/-45/02/45] 16 [03/90/04] 8
~2,830 [45/-45/90/45/-45/90/45/45/90/-45/45/90/-45/02/45] 16 [03/90/03] 7
~3,330 [45/-45/90/45/-45/90/45/45/90/-45/45/90/-45/0/45] 15 [05] 5
~3,830 [45/-45/90/45/-45/90/45/45/90/-45/45/90/-45/0/45] 15 [04] 4
~4,000 [45/-45/90/45/-45/90/45/45/90/-45/45/90/-45/0/45/902] 17 [04] 4
~4,500 [45/-45/90/45/-45/45/90/45/-45/45/90/-45/45] 13 [04] 4
~5,000 [45/-45/90/45/-45/45/90/45/-45/45/90/-45/45] 13 - -
~5,500 [45/-45/90/45/-45/45/90/45/-45/45/90/-45/45] 13 - -
~6,000 [45/-45/90/45/-45/45/90/45/-45/45/90/-45/45] 13 - -
~6,500 [45/-45/90/45/-45/45/90/45/-45/45/90/-45/45] 13 - -
~7,000 [45/-45/90/45/-45/45/90/45/-45/45/90/-45] 12 - -
~7,500 [45/-45/90/45/-45/45/90/45/-45/45/90] 11 - -
~8,000 [45/-45/90/45/-45/45/90/45/-45/45] 10 - -
~8,500 [45/-45/90/45/-45/45/90/45/-45] 9 - -
~9,000 [45/-45/90/45/-45/45/90/45] 8 - -
~9,500 [45/-45/90/45/-45/45/90] 7 - -
~10,500 [45/-45/90/45/-45/45] 6 - -
~11,000 [45/-45/90/45/-45] 5 - -