Table 2. Three atmospheric corrosion estimation methods used in the study

Variables Atmospheric corrosivity models
Classification scheme Statistical model
PACER LIME ICP CORRAG
Dist ○
Cldepo ○
Clprcp ○
Prcp ○ ○
Tavg ○
Rhav ○
Ahav ○
TOWc ○
SO2 ○ ○ ○
PM10 ○
O3 ○
PM10 was used instead of the TSP (total suspended particles), which is a variable for PACER LIME.